1、温差的影响。换热器法兰、筒体、螺栓、管盒、垫片之间存在温差,形成各部分胀缩不均匀,形成换热器机组法兰垫片泄漏。
2、温度对资料功能的影响。换热单元的起浮头盖与起浮头管板之间的密封是将两个钩环夹紧在管板的背面形成钩法兰,并通过螺栓衔接。钩法兰通过整体加工切割成两片。假如钩环,螺栓和其他资料使用过程中的长时间暴露在100~120℃高温环境,其力学功能将会下降,蠕变和应力松懈会产生(相同的不同部分的热膨胀钩卡也不同),这将减少螺栓张力。它将直接导致垫上法兰压缩量的减少和泄漏的产生。
3、温度对垫片的影响。呈现这个问题的原因是热交换单元的法兰是用耐油石棉橡胶片做的。长时间在55~120℃的高温下,垫片会老化,失去弹性,导致垫片泄漏。
About Us
Company Honor Organization CultureProduct
General-purpose polystyrene equipment Reaction stirring equipment Heat exchange equipment Fermentation, filtration and extraction equipment Drying, dispersion and mixing equipment Distillation concentration equipment Others Evaporation concentration equipment Steaming and hydrolyzing equipment Crushing equipment Pressing and extracting equipment Cooling equipment Conveying equipment Pressure vessel Melt crystallization technology and equipmentPerformance