操作方法
先将电源翻开后,承认电源,气源是否正常供应,手动放气阀门是否处于关闭情况,除气泡时间是否调整完毕,加热温度是否设定到所需温度。首要,操作人员必需求观查进气压力表,将进气调理阀门的压力调整到需求的数值,松开盖门,然后开向侧方,再将产品依次放入罐内,摆放规整后将盖门锁住。翻开进气阀,然后按下启停按钮,此刻进入除气泡阶段,设定时间抵达后蜂鸣器报警指示提醒操作人员此次消泡完结,等气浮掉下后再次按启停按钮,一起关闭进气阀门,当罐内气压与罐外气压平恒时翻开即可翻开盖门取出产品,此刻除气泡工序完结,如除气泡作用不抱负可重复以上步聚。
注意事项
机器内处于高压情况时制止松开盖门,机器工作时请注意人身安全。
定时查看密封圈、加热管等设备,如有损坏停止使用,联络厂家。
有闻到反常焦味时请及时关掉电源。
充气加压前必须旋紧盖门到位
About Us
Company Honor Organization CultureProduct
General-purpose polystyrene equipment Reaction stirring equipment Heat exchange equipment Fermentation, filtration and extraction equipment Drying, dispersion and mixing equipment Distillation concentration equipment Others Evaporation concentration equipment Steaming and hydrolyzing equipment Crushing equipment Pressing and extracting equipment Cooling equipment Conveying equipment Pressure vessel Melt crystallization technology and equipmentPerformance